Part Number Hot Search : 
SM5852 D2412 2SC55 SG3846 GH22NS30 LDBK3833 F105K FX629J
Product Description
Full Text Search
 

To Download FWA-125B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1-17-01 sb00233 form no. fwa 150 page 1 of 2 bif doc #720002 bussmann fwa 150v 70-1000a electrical characteristics ordering information dimensions rated i 2 t (a 2 sec) carton current clearing watts part carton weight figure type rms-amps pre-arc at 150v loss number qty. (lbs) number 70 470 4000 6.9 fwa-70b _____________________________________________________________________________________ 80 670 6000 7.7 fwa-80b ____________________________________________________________________________________ __ 100 1200 12000 9.0 fwa-100b ____________________________________________________________________________________ __ 125 1870 18000 11.2 FWA-125B _____________________________________________________________________________________ 150 2700 26000 13.5 fwa-150b 1 0.18 fig. 1 _____________________________________________________________________________________ 200 4780 45000 17.6 fwa-200b _____________________________________________________________________________________ 250 7470 70000 22.5 fwa-250b _____________________________________________________________________________________ fwa 300 10760 100000 27.0 fwa-300b _______________________________________________________________________________ _____ 150v 350 15700 140000 30.6 fwa-350b _____________________________________________________________________________________ 400 20300 180000 35.2 fwa-400b __________________________________________________________________________________________________________________________ 500 39000 120000 35.0 fwa-500a _____________________________________________________________________________________ 600 46000 140000 47.0 fwa-600a _____________________________________________________________________________________ 700 75000 220000 49.0 fwa-700a 5 2.42 fig. 2 _____________________________________________________________________________________ 800 92000 280000 58.0 fwa-800a _____________________________________________________________________________________ 1000 170000 510000 60.0 fwa-1000a 150 102 70 22 1.5 1.0 0.5 0.3 0.2 0.15 eg k 1) 2) u l e g 200 100 100 150 50 300 k p 1.0 0.8 0.4 0.5 0.6 0.3 0.2 0.1 30 40 50 60 70 80 90 100% i b 1) 500-1000 amp range 2) 70-400 amp range total clearing i 2 t the total clearing i 2 t at rated voltage and at power factor of 15% are given in the electrical characteristics. for other volt- ages, the clearing i 2 t is found by multi- plying by correction factor, k , given as a function of applied working voltage, e g , (rms). arc voltage this curve gives the peak arc voltage, u l , which may appear across the fuse during its operation as a function of the applied working voltage, e g , (rms) at a power factor of 15%. power losses watts loss at rated current is given in the electrical characteristics. the curve allows the calculation of the power losses at load currents lower than the rated current . the correction factor, k p , is given as a function of the rms load current, i b , in % of the rated current . n interrupting rating 100ka rms symmetrical for ampere ratings 70-400. 1 kg = 2.2 lbs 1 lb = 0.45 kg n interrupt rating 200ka rms symmetrical for ampere ratings 450-1000. n watts loss provided at rated current. n 150 vdc u.l. recognition on 70 through 800 amperes only. consult bussmann for additional ratings. electrical characteristics
the only controlled copy of this bif document is the electronic read-only version located on the bussmann network drive. all ot her copies of this document are by definition uncontrolled. this bulletin is intended to clearly present comprehensive product data and provide technical information that will help the en d user with design applications. bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. buss mann also reserves the right to change or update, without notice, any technical information contained in this bulletin. once a product has been selected, it should be tested by the user in all possible applications. form no. fwa 150 page 2 of 2 bif doc #720002 bussmann fwa 150v 70-1000a 2.656 1.936 2.188 1.156 0.312 0.438 0.750 1.000 0.125 dimensions fig. 1: 70-400 amp range 1.500 0.250 3.500 2.438 1.250 1.000 0.406 fig. 2: 500-1000 amp range dimension in inches. 1mm = 0.0394 1 = 25.4mm 1-17-01 sb00233


▲Up To Search▲   

 
Price & Availability of FWA-125B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X